Availability: | |
---|---|
Quantity: | |
Model:PCM-LB4S80A-AY143 (LF-4S80A) | ||
Test item(Test at normal temperature 25±2℃ ) | Criterion | |
Voltage | Charging voltage | DC:14.4V CC/CV(3.6V/Cell)4s |
Supply Current | Normal operating mode current:Fuel gauge in NORMAL mode. ILOAD >Sleep Current | ≤50uA |
Maximal continuous charging current | 80A | |
Maximal continuous discharging current | 80A | |
Balance current for single cell | 36±10mA | |
Over-charge Protection (single cell) | Balance voltage for single cell | 3.6V±0.05V |
Over charge detection voltage | 3.9±0.025V | |
Over charge detection delay time | 0.5S—2S | |
Over charge release voltage | 3.8±0.025V | |
Over discharge protection (single cell) | Over discharge detection voltage | 2.0±0.05V |
Over discharge detection delay time | 10—200mS | |
Over discharge release voltage | 2.50±0.05V | |
Over current protection | Discharge Over current detection current | 250±30A |
Detection delay time | 10ms—50ms | |
Release condition | Cut load,Auto Recovery | |
Short protection | Detection condition | Exterior short circuit |
Detection delay time | 100-600us | |
Release condition | Cut load | |
Resistance | Main loop electrify resistance | ≤20mΩ |
Temperature | high temperature discharge protection | '65±10℃ |
Operating Temperature Range | -40~+85℃ | |
Storage Temperature Range | -40~+125℃ | |
SIZE:L135*W95*T8.5 mm | ||
NTC: / Temperature switch:/ Weak current switch:/ Activation Method:/ |
Model:PCM-LB4S80A-AY143 (LF-4S80A) | ||
Test item(Test at normal temperature 25±2℃ ) | Criterion | |
Voltage | Charging voltage | DC:14.4V CC/CV(3.6V/Cell)4s |
Supply Current | Normal operating mode current:Fuel gauge in NORMAL mode. ILOAD >Sleep Current | ≤50uA |
Maximal continuous charging current | 80A | |
Maximal continuous discharging current | 80A | |
Balance current for single cell | 36±10mA | |
Over-charge Protection (single cell) | Balance voltage for single cell | 3.6V±0.05V |
Over charge detection voltage | 3.9±0.025V | |
Over charge detection delay time | 0.5S—2S | |
Over charge release voltage | 3.8±0.025V | |
Over discharge protection (single cell) | Over discharge detection voltage | 2.0±0.05V |
Over discharge detection delay time | 10—200mS | |
Over discharge release voltage | 2.50±0.05V | |
Over current protection | Discharge Over current detection current | 250±30A |
Detection delay time | 10ms—50ms | |
Release condition | Cut load,Auto Recovery | |
Short protection | Detection condition | Exterior short circuit |
Detection delay time | 100-600us | |
Release condition | Cut load | |
Resistance | Main loop electrify resistance | ≤20mΩ |
Temperature | high temperature discharge protection | '65±10℃ |
Operating Temperature Range | -40~+85℃ | |
Storage Temperature Range | -40~+125℃ | |
SIZE:L135*W95*T8.5 mm | ||
NTC: / Temperature switch:/ Weak current switch:/ Activation Method:/ |