Availability: | |
---|---|
Quantity: | |
Model:PCM-L04S30-G28 | ||
Test item(Test at normal temperature 25±2℃ ) | Criterion | |
Communication Interface | RS232 | |
Voltage | Charging voltage | DC:14.4V CC/CV(3.6V/Cell)4S |
Supply Current | Normal operating mode current: Fuel gauge in NORMAL mode. ILOAD >Sleep Current | ≤600uA |
Low-power operating mode current: Fuel gauge in SLEEP mode. ILOAD < Sleep Current | ≤200 uA | |
Maximal continuous charging current | 20A | |
Maximal continuous discharging current | 20A | |
Balance current for single cell | 36mA±10mA | |
Over-charge Protection (single cell) | Balance voltage for single cell | 3.55V±0.025V |
Over charge detection voltage | 3.90±0.05V | |
Over charge detection delay time | 0.5S—2S | |
Over charge release voltage | 3.50±0.05V | |
Over discharge protection (single cell) | Over discharge detection voltage | 2.00±0.07V |
Over discharge detection delay time | 0.5S—2S | |
Over discharge release voltage | 2.50±0.1V | |
Over Current protection (Battery pack) | Discharge Over current detection current | 40±10A |
Detection delay time | 200-600us | |
Release condition | Cut load,Auto Recovery | |
Short protection | Detection condition | Exterior short circuit |
Detection delay time | 200-600us | |
Release condition | Cut load | |
Resistance | Main loop electrify resistance | ≤20mΩ |
Temperature | high temperature discharge protection | '65℃ |
Discharge temperature detection delay time | '5s | |
high temperature discharge recover protection | 45℃ | |
high temperature charge protection | '65℃ | |
Charge temperature detection delay time | '5s | |
high temperature charge recover protection | '45℃ | |
Operating Temperature Range | -20~+85℃ | |
Storage Temperature Range | -40~+125℃ | |
SIZE:L80*W60*T8mm | ||
NTC:/ Temperature switch:65 ℃ (the batteries temperature) Weak current switch:/ Activation Method:/ |
Model:PCM-L04S30-G28 | ||
Test item(Test at normal temperature 25±2℃ ) | Criterion | |
Communication Interface | RS232 | |
Voltage | Charging voltage | DC:14.4V CC/CV(3.6V/Cell)4S |
Supply Current | Normal operating mode current: Fuel gauge in NORMAL mode. ILOAD >Sleep Current | ≤600uA |
Low-power operating mode current: Fuel gauge in SLEEP mode. ILOAD < Sleep Current | ≤200 uA | |
Maximal continuous charging current | 20A | |
Maximal continuous discharging current | 20A | |
Balance current for single cell | 36mA±10mA | |
Over-charge Protection (single cell) | Balance voltage for single cell | 3.55V±0.025V |
Over charge detection voltage | 3.90±0.05V | |
Over charge detection delay time | 0.5S—2S | |
Over charge release voltage | 3.50±0.05V | |
Over discharge protection (single cell) | Over discharge detection voltage | 2.00±0.07V |
Over discharge detection delay time | 0.5S—2S | |
Over discharge release voltage | 2.50±0.1V | |
Over Current protection (Battery pack) | Discharge Over current detection current | 40±10A |
Detection delay time | 200-600us | |
Release condition | Cut load,Auto Recovery | |
Short protection | Detection condition | Exterior short circuit |
Detection delay time | 200-600us | |
Release condition | Cut load | |
Resistance | Main loop electrify resistance | ≤20mΩ |
Temperature | high temperature discharge protection | '65℃ |
Discharge temperature detection delay time | '5s | |
high temperature discharge recover protection | 45℃ | |
high temperature charge protection | '65℃ | |
Charge temperature detection delay time | '5s | |
high temperature charge recover protection | '45℃ | |
Operating Temperature Range | -20~+85℃ | |
Storage Temperature Range | -40~+125℃ | |
SIZE:L80*W60*T8mm | ||
NTC:/ Temperature switch:65 ℃ (the batteries temperature) Weak current switch:/ Activation Method:/ |