Availability: | |
---|---|
Quantity: | |
Model:PCM-L04S07-D35(4S) | ||
Test item(Test at normal temperature 25±2℃ ) | Criterion | |
Communication Interface | SMBUS | |
Voltage | Charging voltage | DC: 14.4V CC/CV(3.6V/1cell) |
Supply Current | Normal operating mode current: Fuel gauge in NORMAL mode. ILOAD >Sleep Current | ≤600uA |
Low-power operating mode current: Fuel gauge in SLEEP mode. ILOAD < Sleep Current | ≤200 uA | |
Maximal continuous charging current | 7A | |
Maximal continuous discharging current | 7A | |
Balance current for single cell | / | |
Over-charge Protection (single cell) | Balance voltage for single cell | / |
Over charge detection voltage | 3.75±0.025V | |
Over charge detection delay time | 0.5S—2S | |
Over charge release voltage | 3.50±0.05V | |
Over discharge protection (single cell) | Over discharge detection voltage | 2.20±0.10V |
Over discharge detection delay time | 0.5S—2S | |
Over discharge release voltage | 2.5±0.1V | |
Over Current protection (Battery pack) | Over current detection current | 20±3A |
Detection delay time | 0.5S—2S | |
Release condition | Cut load,Auto Recovery | |
Short protection | Detection condition | Exterior short circuit |
Detection delay time | 200-600us | |
Release condition | Cut load | |
Resistance | Main loop electrify resistance | ≤50mΩ |
Temperature | Operating Temperature Range | -40~+85℃ |
Storage Temperature Range | -40~+125℃ | |
Discharging Temperature Protection | 65℃ | |
SIZE:L66*W16.6*T4mm | ||
NTC:/ Temperature switch:/ Weak current switch:/ Activation Method:/ |
Model:PCM-L04S07-D35(4S) | ||
Test item(Test at normal temperature 25±2℃ ) | Criterion | |
Communication Interface | SMBUS | |
Voltage | Charging voltage | DC: 14.4V CC/CV(3.6V/1cell) |
Supply Current | Normal operating mode current: Fuel gauge in NORMAL mode. ILOAD >Sleep Current | ≤600uA |
Low-power operating mode current: Fuel gauge in SLEEP mode. ILOAD < Sleep Current | ≤200 uA | |
Maximal continuous charging current | 7A | |
Maximal continuous discharging current | 7A | |
Balance current for single cell | / | |
Over-charge Protection (single cell) | Balance voltage for single cell | / |
Over charge detection voltage | 3.75±0.025V | |
Over charge detection delay time | 0.5S—2S | |
Over charge release voltage | 3.50±0.05V | |
Over discharge protection (single cell) | Over discharge detection voltage | 2.20±0.10V |
Over discharge detection delay time | 0.5S—2S | |
Over discharge release voltage | 2.5±0.1V | |
Over Current protection (Battery pack) | Over current detection current | 20±3A |
Detection delay time | 0.5S—2S | |
Release condition | Cut load,Auto Recovery | |
Short protection | Detection condition | Exterior short circuit |
Detection delay time | 200-600us | |
Release condition | Cut load | |
Resistance | Main loop electrify resistance | ≤50mΩ |
Temperature | Operating Temperature Range | -40~+85℃ |
Storage Temperature Range | -40~+125℃ | |
Discharging Temperature Protection | 65℃ | |
SIZE:L66*W16.6*T4mm | ||
NTC:/ Temperature switch:/ Weak current switch:/ Activation Method:/ |