Availability: | |
---|---|
Quantity: | |
Model:PCM-L04S100-G20 (LI-4S110A) | ||
Test item(Test at normal temperature 25±2℃ ) | Criterion | |
Voltage | Charging voltage | DC:16.8V CC/CV(4.2V/Cell)4S |
Supply Current | Normal operating mode current:Fuel gauge in NORMAL mode. ILOAD >Sleep Current | ≤50uA |
Maximal continuous charging current | 110A | |
Maximal continuous discharging current | 110A | |
Balance current for single cell | 42mA±5mA | |
Over-charge Protection (single cell) | Balance voltage for single cell | 4.2V±0.025V |
Over charge detection voltage | 4.25±0.025V | |
Over charge detection delay time | 0.5S—2S | |
Over charge release voltage | 4.05±0.05V | |
Over discharge protection (single cell) | Over discharge detection voltage | 2.5±0.07V |
Over discharge detection delay time | 0.5S—2S | |
Over discharge release voltage | 3.00±0.1V | |
Over current protection | Discharge Over current detection current | 300±50A |
Detection delay time | 200-600us | |
Release condition | Cut load,Auto Recovery | |
Short protection | Detection condition | Exterior short circuit |
Detection delay time | 200-600us | |
Release condition | Cut load | |
Resistance | Main loop electrify resistance | ≤20mΩ |
Temperature | high temperature discharge protection | '65℃ |
Operating Temperature Range | -40~+85℃ | |
Storage Temperature Range | -40~+125℃ | |
SIZE:L200*W115*T12mm | ||
NTC: / Temperature switch:65 ℃ (the batteries temperature) Weak current switch:/ Activation Method:/ |
Model:PCM-L04S100-G20 (LI-4S110A) | ||
Test item(Test at normal temperature 25±2℃ ) | Criterion | |
Voltage | Charging voltage | DC:16.8V CC/CV(4.2V/Cell)4S |
Supply Current | Normal operating mode current:Fuel gauge in NORMAL mode. ILOAD >Sleep Current | ≤50uA |
Maximal continuous charging current | 110A | |
Maximal continuous discharging current | 110A | |
Balance current for single cell | 42mA±5mA | |
Over-charge Protection (single cell) | Balance voltage for single cell | 4.2V±0.025V |
Over charge detection voltage | 4.25±0.025V | |
Over charge detection delay time | 0.5S—2S | |
Over charge release voltage | 4.05±0.05V | |
Over discharge protection (single cell) | Over discharge detection voltage | 2.5±0.07V |
Over discharge detection delay time | 0.5S—2S | |
Over discharge release voltage | 3.00±0.1V | |
Over current protection | Discharge Over current detection current | 300±50A |
Detection delay time | 200-600us | |
Release condition | Cut load,Auto Recovery | |
Short protection | Detection condition | Exterior short circuit |
Detection delay time | 200-600us | |
Release condition | Cut load | |
Resistance | Main loop electrify resistance | ≤20mΩ |
Temperature | high temperature discharge protection | '65℃ |
Operating Temperature Range | -40~+85℃ | |
Storage Temperature Range | -40~+125℃ | |
SIZE:L200*W115*T12mm | ||
NTC: / Temperature switch:65 ℃ (the batteries temperature) Weak current switch:/ Activation Method:/ |