Availability: | |
---|---|
Quantity: | |
Model:AY-LB10S5A-T013 | ||
Test item(Test at normal temperature 25±2℃ ) | Criterion | |
Communication Interface | SMBUS | |
Voltage | Charging voltage | DC:37.8V CC/CV(4.2v/Cell)9s |
Capacity | Designing battery capacity(PCM) | /Ah |
Supply Current | Normal operating mode current:Fuel gauge in NORMAL mode. ILOAD >Sleep Current | ≤860uA |
Low-power operating mode current:Fuel gauge in SLEEP mode.ILOAD < Sleep Current | ≤430 uA | |
Low-power operating mode current:Fuel gauge in FULLSLEEP mode.ILOAD < Sleep Current | ≤12uA | |
Maximal continuous charging current | 4.5A | |
Maximal continuous discharging current | 4.5A | |
Balance current for single cell | 42±10mA | |
Over-charge Protection (single cell) | Balance voltage for single cell | 4.0V±0.05V |
Over charge detection voltage | 4.30±0.05V | |
Over charge detection delay time | 0.5S—2S | |
Over charge release voltage | 4.10±0.1V | |
Over discharge protection (single cell) | Over discharge detection voltage | 2.8±0.05V |
Over discharge detection delay time | 0.5S—2S | |
Over discharge release voltage | 3.0±0.1V | |
Over Current protection (Battery pack) | ChargeOver current detection current | 10±3A |
Detection delay time | 0.5S—2S | |
Discharge Over current detection current | 20±5A | |
Detection delay time | 0.5S—2S | |
Release condition | Cut load,Auto Recovery | |
Short protection | Detection condition | Exterior short circuit |
Detection delay time | 200-600us | |
Release condition | Cut load | |
Resistance | Main loop electrify resistance | ≤30mΩ |
Temperature | discharge temperature protection | '-10~+65℃ |
charge temperature protection | 0~+60℃ | |
Operating Temperature Range | -40~+85℃ | |
Storage Temperature Range | -40~+125℃ | |
SIZE:L65*W35*T5 mm | ||
NTC:10KNTC B=3435 Temperature switch:/ ℃ (the batteries temperature) Weak current switch:/ Activation Method:/ |
Model:AY-LB10S5A-T013 | ||
Test item(Test at normal temperature 25±2℃ ) | Criterion | |
Communication Interface | SMBUS | |
Voltage | Charging voltage | DC:37.8V CC/CV(4.2v/Cell)9s |
Capacity | Designing battery capacity(PCM) | /Ah |
Supply Current | Normal operating mode current:Fuel gauge in NORMAL mode. ILOAD >Sleep Current | ≤860uA |
Low-power operating mode current:Fuel gauge in SLEEP mode.ILOAD < Sleep Current | ≤430 uA | |
Low-power operating mode current:Fuel gauge in FULLSLEEP mode.ILOAD < Sleep Current | ≤12uA | |
Maximal continuous charging current | 4.5A | |
Maximal continuous discharging current | 4.5A | |
Balance current for single cell | 42±10mA | |
Over-charge Protection (single cell) | Balance voltage for single cell | 4.0V±0.05V |
Over charge detection voltage | 4.30±0.05V | |
Over charge detection delay time | 0.5S—2S | |
Over charge release voltage | 4.10±0.1V | |
Over discharge protection (single cell) | Over discharge detection voltage | 2.8±0.05V |
Over discharge detection delay time | 0.5S—2S | |
Over discharge release voltage | 3.0±0.1V | |
Over Current protection (Battery pack) | ChargeOver current detection current | 10±3A |
Detection delay time | 0.5S—2S | |
Discharge Over current detection current | 20±5A | |
Detection delay time | 0.5S—2S | |
Release condition | Cut load,Auto Recovery | |
Short protection | Detection condition | Exterior short circuit |
Detection delay time | 200-600us | |
Release condition | Cut load | |
Resistance | Main loop electrify resistance | ≤30mΩ |
Temperature | discharge temperature protection | '-10~+65℃ |
charge temperature protection | 0~+60℃ | |
Operating Temperature Range | -40~+85℃ | |
Storage Temperature Range | -40~+125℃ | |
SIZE:L65*W35*T5 mm | ||
NTC:10KNTC B=3435 Temperature switch:/ ℃ (the batteries temperature) Weak current switch:/ Activation Method:/ |