Availability: | |
---|---|
Quantity: | |
Model: PCM-L25S60-G31 (LI-25S60A) ver: A | ||
Test item(Test at normal temperature 25±2℃ ) | Criterion | |
Voltage | Charging voltage | DC:105V CC/CV(4.2v/Cell)25s |
Supply Current | Normal operating mode current:Fuel gauge in NORMAL mode. ILOAD >Sleep Current | ≤50uA |
Maximal continuous charging current | 60A | |
Maximal continuous discharging current | 60A | |
Balance current for single cell | 42±10mA | |
Over-charge Protection (single cell) | Balance voltage for single cell | 4.2V±0.05V |
Over charge detection voltage | 4.25±0.05V | |
Over charge detection delay time | 0.5S—2S | |
Over charge release voltage | 4.15±0.1V | |
Over discharge protection (single cell) | Over discharge detection voltage | 2.5±0.05V |
Over discharge detection delay time | 10—200mS | |
Over discharge release voltage | 2.75±0.1V | |
Current protection (Battery pack) | ChargeOver current detection current | / |
Detection delay time | / | |
Discharge Over current detection current | 200±30A | |
Detection delay time | 5ms—50ms | |
Release condition | Cut load,Auto Recovery | |
Short protection | Detection condition | Exterior short circuit |
Detection delay time | 200-600us | |
Release condition | Cut load | |
Resistance | Main loop electrify resistance | ≤20mΩ |
Temperature | high temperature discharge protection | 65℃ |
Operating Temperature Range | -20~+85℃ | |
Storage Temperature Range | -40~+125℃ | |
SIZE :L160*W110*T15mm | ||
NTC: / Temperature switch: 65 ℃ (the batteries temperature) Weak current switch:/ Activation Method:/ |
Model: PCM-L25S60-G31 (LI-25S60A) ver: A | ||
Test item(Test at normal temperature 25±2℃ ) | Criterion | |
Voltage | Charging voltage | DC:105V CC/CV(4.2v/Cell)25s |
Supply Current | Normal operating mode current:Fuel gauge in NORMAL mode. ILOAD >Sleep Current | ≤50uA |
Maximal continuous charging current | 60A | |
Maximal continuous discharging current | 60A | |
Balance current for single cell | 42±10mA | |
Over-charge Protection (single cell) | Balance voltage for single cell | 4.2V±0.05V |
Over charge detection voltage | 4.25±0.05V | |
Over charge detection delay time | 0.5S—2S | |
Over charge release voltage | 4.15±0.1V | |
Over discharge protection (single cell) | Over discharge detection voltage | 2.5±0.05V |
Over discharge detection delay time | 10—200mS | |
Over discharge release voltage | 2.75±0.1V | |
Current protection (Battery pack) | ChargeOver current detection current | / |
Detection delay time | / | |
Discharge Over current detection current | 200±30A | |
Detection delay time | 5ms—50ms | |
Release condition | Cut load,Auto Recovery | |
Short protection | Detection condition | Exterior short circuit |
Detection delay time | 200-600us | |
Release condition | Cut load | |
Resistance | Main loop electrify resistance | ≤20mΩ |
Temperature | high temperature discharge protection | 65℃ |
Operating Temperature Range | -20~+85℃ | |
Storage Temperature Range | -40~+125℃ | |
SIZE :L160*W110*T15mm | ||
NTC: / Temperature switch: 65 ℃ (the batteries temperature) Weak current switch:/ Activation Method:/ |